: Provides 2 channels of 0–10V analog voltage (50mA limit) typically assigned to proportional gas valves.
If your device has a green LED, a laser aperture, and a D-Sub (serial) connector, you are in the right place.
The BCL4562 is the central hub in a modular system. The BCL4562 is designed as the I/O terminal for the FSCUT1000 series, which integrates motion control and height control in one board. It works with the following components: bcl 4562 manual full
To make your physical BCL4562 wiring communicate correctly with your PC, you must perform primary configurations inside the Shanghai Bochu Friendess CypOne software platform . Step-by-Step Configuration Strategy
Supports both Normally Open (NO) and Normally Closed (NC) low-level active signals. Output Ports: 8 Common Outputs: Relay outputs rated for 30V DC / 5A . 2 DA Outputs: 0~10V analog signals at 50mA. : Provides 2 channels of 0–10V analog voltage
8 relay outputs (30V DC/5A); 2 DA outputs (0–10V, 50mA); 1 PWM output (5V/24V optional) Interface Type 32-bit PCI bus Application Low-power fiber laser cutting machines (up to 3000W) Key Installation & Usage Tips
A community-uploaded 76-page version is also available for viewing on Scribd . Pro-Tip for Installation The BCL4562 is designed as the I/O terminal
: Using original Friendess adapter boards like the BCL4562 is recommended to maintain a low-latency, stable signal path, which helps prevent issues like random laser firing or cutting speed fluctuations. Common Applications
: Six common inputs manage ancillary diagnostic equipment. They can be configured as Normally Open (NO) or Normally Closed (NC) inside the system setup. Common applications include: Water chiller error loop Assist gas pressure monitoring switch Laser source alarm line Cycle Start / E-Stop external physical buttons Output Ports Configuration