Before mounting the new compressor, the existing system must be in perfect condition. This includes flushing the system to remove any debris or old oil, replacing the filter drier, and pressure testing all components for leaks.
All brazing operations must be performed with a continuous flow of an inert gas, like nitrogen, through the system. This prevents the formation of copper oxide (scale) inside the tubing, which can contaminate the oil and cause a compressor burnout. Brazing should be done with a containing a high concentration of silver (e.g., 15% or 45%). The low-carbon steel process tube should be brazed using a flux-coated rod or one with 2% to 5% silver ; do not use copper-phosphorus rods on steel as they will not bond properly. l68wu1 compressor pdf
Ensure evaporating temperatures fall within the -35°C to -10°C (-31°F to 14°F) window.
When evaluating the L68WU1 for replacement or system design, understanding its thermodynamic performance is critical. The figures below reflect standard ASHRAE rating conditions for low back pressure configurations. Performance Metrics Rating / Value Testing Condition ~160 to 185 Watts (540 - 630 BTU/hr) ASHRAE (Evap. Temp: -23.3°C / -10°F) Displacement Nominal mechanical volume Coefficient of Performance (COP) 1.20 - 1.40 W/W High-efficiency rating tier Oil Charge 160 - 200 ml Mineral or POE (Polyolester) based on refrigerant 3. Electrical Data and Wiring Diagram Elias sat up, his joints popping
: By using R290, the L68WU1 operates with a thermodynamic efficiency that often surpasses older synthetic refrigerants. Operating Conditions
The Donper L68WU1 is a reciprocating refrigeration compressor engineered for high-efficiency cooling in commercial and residential refrigeration applications. As a prominent component in the Donper Compressor series, the L68WU1 is specifically designed to work with R290 refrigerant (propane) Before mounting the new compressor, the existing system
Connected to the main run winding, handles continuous current during operation. Essential Start Components:
If you are looking for specific replacement parts or a detailed manual for the , it is highly recommended to consult a certified HVAC-R distributor to obtain the most recent PDF documentation from Donper.
Install service gauges. Check for low low-side pressure and low high-side pressure.
RSCR (Resistance Start Capacitor Run) or RSIR (Resistance Start Induction Run).